Project Background
To meet a new-energy motor manufacturer's requirements for standardized testing of core drive-motor metrics such as external characteristics and efficiency maps, this system builds a motor back-to-back test platform based on bidirectional energy circulation. Independently developed host software coordinates multiple devices, runs automated test flows, and generates data reports, meeting national test standards including GB/T 18488.
System Architecture
Power Unit
Motor under test: Founder three-in-one integrated motor (peak power 120 kW)
Load unit: GTAKE permanent-magnet synchronous motor + Inovance IS6500 bidirectional DC power supply (energy-regeneration efficiency ≥95%)
Measurement System
HBM T40 torque and speed sensor (accuracy ±0.1%)
NI data-acquisition system (16 channels acquired synchronously)
Auxiliary System
Intelligent water-cooling unit (flow adjustable from 0-30 L/min)
Communication Network
ZLG USB-CAN card (controls motor operation and acquires motor status parameters)
RS485 bus (adjusts power-supply output / cooling flow)
Software Functions
1. Multi-Protocol Device Coordination
CAN-Bus Device Control
Parses the motor controller's proprietary protocol and uses CAN2.0B frames to place the GTAKE motor in torque or speed mode
Reads more than 50 status parameters in real time, including motor temperature, DC-bus voltage, and phase current (refresh rate 100 ms)
RS485 Serial-Port Management
Sends Modbus-RTU commands to control the output characteristics of the Inovance power supply (0-800 V/±500 A)
Adjusts water-cooling unit flow (a PID algorithm holds the motor coolant inlet temperature at 40±1°C)
2. Automated Test Flow
External-Characteristics Test Module
Test sequences developed to GB/T 18488-2015
Supports special conditions such as locked-rotor testing and peak-power duration checks
Efficiency-MAP Test
Operating points are scanned automatically with the four-point method:
Speed range 0-8000 rpm (100 rpm step)
Torque range -300 Nm to +300 Nm (10 Nm step)
Motor efficiency is calculated in real time:
η(%) = (output mechanical power)/(input electric power) ×100
= (2π×torque×speed/9550)/(voltage×current) ×100
3. Data Management and Report Generation
Live Data Dashboard
Displays the efficiency MAP in sync
Compares trends of key parameters (for example, efficiency-decay curves at different speeds)
Intelligent Reporting
Automatically generates test reports that meet the customer's requirements (test conditions, raw data, and characteristic curves)
Automatically marks abnormal data points (an alarm is raised when efficiency deviates by more than 2%)
4. Safety Protection
Three-level safety protection:
Hardware level: the emergency-stop button cuts power directly
Protocol level: CAN-bus out-of-limit protection (for example, load is reduced immediately if speed deviates beyond ±5%)
Software level: the NI data-acquisition system monitors insulation resistance in real time
Technical Specifications
Test accuracy:
Torque measurement error ≤±0.3% FS
Efficiency calculation error ≤±0.5%
Testing efficiency:
Full MAP scan time < 4 hours (traditional methods require 12 hours)
System extensibility:
Supports import of custom operating-condition files in CSV format
A CAN FD protocol upgrade interface is reserved
Application Value
This system has been applied to type testing of products such as new-energy passenger-vehicle drive motors and in-wheel motors. It has markedly improved the accuracy and traceability of test data and provides core data support for motor energy-efficiency optimization.