Where several valves or several points must be controlled together, a stack of single-channel drivers iscostly, takes a lot of space, and is awkward to wire. The FC-T4 is designed for that problem.Four channels in one unit, with several command types and adjustable parameters. A display and keys support local viewing and setup. RS485 and Modbus RTU are standard, so the driver connects to a host system.At a lower overall cost, it drives proportional solenoid valvesefficiently and accurately.
Specifications
Supply: DC 9–36 V
Command: 4–20 mA / 0–5 V / 0–10 V / RS485
Maximum output current: 2 A
Carrier frequency: 50–5000 Hz
Dither frequency: 0–1250 Hz
Dither amplitude: 0–1000 mA
Ramp time: 0–3200 mA/ms (0 means off)
Self-tuning time: ≤ 5 seconds
Communications: RS485 Modbus RTU
Baud rate: 4800 / 9600 / 38400 / 115200 baud
Operating temperature: −40 to 70 °C
Main strengths
Four channels in one unit:one driver for four proportional valves,so the cost per channel is much lower. It saves cabinet space and simplifies wiring, especially where several valves work together.
Self-tuning:the driver measures coil inductance, DC resistance, and other key parameters, andmatches the control settings in 5 seconds or less, which speeds the step response and reduces overshoot and hysteresis.
Flexible settings:4–20 mA, 0–5 V, 0–10 V, RS485, and other command types, including carrier frequency, dither frequency, dither amplitude, and ramp,so the driver can be matched to different valves.
Easy to install:it can be mounted on aDN35 railinside a cabinet. Screw terminals hold the wiring, and installation is straightforward.
Simple to operate:the display and keys canshow and set parameters locally, which makes commissioning faster.
Wide voltage and current: DC 9–36 V supply, and output current from 0 to 2 A, for proportional valves with no position feedback.
Diagnostics:the driver watches for a lost command, overload, an open solenoid, and over-current. Fault codes are shown on the screen or read over communications,so the cause can be found quickly.
Communications:RS485 with Modbus RTU supportsseveral units in a chain.
Where it is used
Control systems that run several valves together
Automotive solenoid-valve testing
Industrial work where the cost of multi-axis drives needs to come down
Taobao link